The Gardner Bender GDT-311 is a robust and reliable digital multimeter designed for a wide range of electrical testing applications. This 3-function, 11 or 14-range meter (depending on the specific model) provides accurate measurements of AC and DC voltage, as well as resistance, making it suitable for both professional electricians and DIY enthusiasts.
Its key feature is manual ranging, allowing users to select the appropriate measurement range for enhanced precision. The GDT-311 boasts a 3.5-inch display for easy readability, and is capable of measuring resistance up to 2 Meg Ohms. Available through retailers like Amazon and Walmart, this multimeter offers a cost-effective solution for basic electrical troubleshooting and testing needs. Gardner Bender emphasizes safety and provides accessible instruction manuals for all their products, including the GDT-311, available online.
Key Features and Specifications
The Gardner Bender GDT-311 multimeter presents several key features for effective electrical measurement. It offers 3 functions – AC Voltage, DC Voltage, and Resistance – across 11 or 14 ranges, providing versatility for various tasks. The manual ranging system, controlled by a smooth rotary dial, enables precise readings tailored to the specific circuit being tested.
Specifications include AC voltage measurement up to 500V (with 200V and 500V ranges for accuracy), DC voltage measurement capabilities, and resistance measurement up to 2 Meg Ohms. A clear 3.5-inch display ensures easy readability of results. A low battery indicator alerts the user when battery replacement is needed, maintaining accurate readouts. This multimeter is a practical and dependable tool for electrical work, backed by Gardner Bender’s support at 800.624.4320.
Understanding the Display
The GDT-311’s LCD screen clearly presents readings, utilizing specific symbols to indicate measurement units, battery status, and overload conditions for accurate interpretation.
Display Symbols and Their Meanings
The Gardner Bender GDT-311 multimeter utilizes several symbols on its LCD screen to convey important information to the user. Understanding these symbols is crucial for accurate readings and safe operation. A “V” symbol indicates voltage measurement, differentiating between DC (direct current) and AC (alternating current) based on the waveform displayed alongside it. The Ohm symbol, “Ω”, signifies resistance measurement, displaying values up to 2 Meg Ohms.
A low battery symbol alerts the user when battery replacement is necessary to ensure accurate read-outs; An “OL” or “1” display indicates an overload condition, meaning the selected range is insufficient for the measured value; the user should then select a higher range. The display also features a decimal point for precise readings and may include a negative sign (-) to indicate polarity for DC voltage measurements. Familiarizing yourself with these symbols will enhance your ability to effectively utilize the GDT-311 multimeter.
Reading Values on the LCD Screen
The Gardner Bender GDT-311’s 3.5-inch LCD screen provides clear and concise readings for voltage and resistance measurements. When measuring voltage, observe the numerical value alongside the “V” symbol, noting the decimal placement for precision. For resistance, the value is displayed with the “Ω” symbol; remember the GDT-311 measures up to 2 Meg Ohms.
Pay attention to the polarity indication for DC voltage measurements – a negative sign signifies reverse polarity. If the display shows “OL” or “1”, it indicates an overload; immediately switch to a higher range using the rotary dial. Ensure the selected range aligns with the expected value for accurate results. The manual ranging feature allows for precise adjustments, optimizing the display for the specific measurement. Consistent observation of these details will ensure reliable and accurate readings with your GDT-311 multimeter.

Operating Instructions
The GDT-311 multimeter offers three functions: AC/DC voltage and resistance testing. Utilize the rotary dial to select the desired function and appropriate range for accurate measurements.
AC Voltage Measurement
To accurately measure AC voltage with the Gardner Bender GDT-311, begin by selecting the appropriate voltage range on the rotary dial. The GDT-311 provides two AC voltage ranges: 200V and 500V. For measurements expected to be below 200 volts, always utilize the 200V setting to ensure the highest possible resolution and accuracy.
Insert the black test lead into the COM (common) jack and the red test lead into the V (voltage) jack. Carefully connect the test leads to the circuit being measured, ensuring proper polarity is observed. Avoid touching the metal tips of the probes during measurement to prevent inaccurate readings or potential shock.
Read the AC voltage value displayed on the LCD screen. The display will indicate the measured voltage in volts (V). If the reading displays “OL” or “1.”, it indicates an overload – switch to a higher voltage range. Remember safety first, and always disconnect power before making measurements whenever possible.
Selecting the Correct AC Voltage Range (200V/500V)
Proper range selection is crucial for accurate AC voltage measurements with the Gardner Bender GDT-311. The multimeter offers two ranges: 200V and 500V. Begin by estimating the voltage you intend to measure. If you anticipate the AC voltage to be less than 200 volts, always start with the 200V range. This provides the highest resolution and most precise reading for lower voltages.
However, if there’s uncertainty or you suspect the voltage might exceed 200V, immediately select the 500V range. Using a range too low for the applied voltage will result in an overload indication (“OL” or “1;”) on the display, potentially damaging the meter.
Remember, it’s always safer to start with a higher range and then decrease it if necessary, rather than risking damage by starting too low. Accurate range selection ensures reliable and safe operation of your GDT-311 multimeter.
DC Voltage Measurement
Measuring DC voltage with the Gardner Bender GDT-311 is a straightforward process. First, ensure the rotary dial is positioned to a DC voltage (VDC) range. The GDT-311, being a manual ranging multimeter, doesn’t auto-select the range; you must choose it. Begin with a higher range if the expected DC voltage is unknown to avoid potential overload.
Connect the red test lead to the positive (+) terminal of the circuit and the black test lead to the negative (-) terminal. Observe the LCD screen for the DC voltage reading. If the reading is very small or zero, switch to a lower DC voltage range for increased precision.
A stable and accurate reading indicates a successful measurement. Remember to always exercise caution when working with electrical circuits and ensure proper safety procedures are followed.
Resistance Measurement
To measure resistance using the Gardner Bender GDT-311, begin by disconnecting power from the circuit being tested – never measure resistance in a live circuit. Rotate the selector dial to a resistance (Ω) range. The GDT-311 offers resistance measurement up to 2 Meg Ohms. Start with a higher range if the resistance value is unknown, then decrease for better accuracy.
Connect the test leads to the component or circuit section whose resistance you wish to determine. Polarity doesn’t matter when measuring resistance. Observe the LCD screen for the resistance value displayed in Ohms.
If the display shows “OL” or “1”, it indicates an overload – the resistance is higher than the selected range. Switch to a higher resistance range and repeat the measurement. Always ensure the component is isolated for accurate results.
Understanding Resistance Ranges (up to 2 Meg Ohms)
The Gardner Bender GDT-311 multimeter’s resistance measurement capability extends up to 2 Meg Ohms (2,000,000 Ω). Understanding the ranges is crucial for accurate readings. Lower ranges, like 200Ω, are ideal for measuring the resistance of low-value components such as wires or short circuit checks. Higher ranges, approaching 2MΩ, are suitable for testing higher-value resistors or checking insulation resistance.
When the expected resistance is unknown, always start with the highest range. This prevents potential overload damage to the meter. If the reading is very small or zero, gradually decrease the range until a precise reading is obtained. Remember that “OL” indicates the resistance exceeds the selected range, necessitating a switch to a higher setting.
Manual Ranging Explained
The GDT-311 utilizes manual ranging, achieved via a smooth rotary dial, allowing users to select the appropriate range for precise and accurate measurements of voltage and resistance.
How to Use the Rotary Dial for Precise Readings
To obtain accurate readings with the GDT-311, proper use of the rotary dial is crucial. Begin by selecting the range that is higher than the expected value of the circuit you are testing. For instance, if measuring an unknown DC voltage, start with the 500V range.
Slowly rotate the dial to lower ranges until you achieve a reading within a usable scale. The 11 or 14-position dial (depending on the model) allows for fine-tuning. If the display shows “OL” or “1.”, it indicates an overload – immediately switch to a higher range.
Remember: Manual ranging requires the user to estimate the approximate value beforehand. Selecting a range too low will result in an overload, while a range too high may reduce precision. Practice and familiarity with typical circuit voltages and resistances will improve your range selection skills, leading to consistently accurate results with this versatile multimeter.
Benefits of Manual Ranging

The Gardner Bender GDT-311 utilizes manual ranging, offering distinct advantages over auto-ranging multimeters. Manual ranging provides users with greater control over the measurement process, fostering a deeper understanding of the circuit being tested. By actively selecting the appropriate range, technicians can avoid potential inaccuracies caused by automatic range selection algorithms.
This method also enhances troubleshooting capabilities, as it forces a conscious assessment of expected values. The smooth rotary dial facilitates precise adjustments, allowing for optimized readings. Furthermore, manual ranging often results in faster measurement stabilization compared to auto-ranging systems.
Ultimately, the GDT-311’s manual ranging system empowers users with increased precision, control, and a more comprehensive grasp of electrical measurements, making it a valuable tool for both professionals and hobbyists.

Safety Precautions
Always prioritize safety when using the GDT-311. Gardner Bender disclaims liability for incidental damage, emphasizing the importance of following all safety guidelines carefully.

General Safety Guidelines
Prior to operating the Gardner Bender GDT-311, carefully review these essential safety guidelines to ensure personal safety and prevent damage to the meter or connected equipment. Always inspect the test leads for any signs of damage – cracks, fraying, or exposed wire – before each use, replacing them immediately if compromised.
Never attempt to measure voltages exceeding the meter’s specified limits (500V AC/DC), as this poses a significant electrical shock hazard. When working with live circuits, exercise extreme caution and adhere to established electrical safety procedures. Disconnect power to the circuit under test whenever possible before making measurements.
Avoid operating the meter in wet or damp environments, and never touch the metal probes while the meter is connected to a live circuit. Do not use the meter in hazardous locations where flammable gases or vapors may be present. This meter is intended for indoor use only. Always wear appropriate personal protective equipment (PPE), such as safety glasses, when working with electrical circuits.
Battery Replacement and Low Battery Indicator
The Gardner Bender GDT-311 utilizes batteries to power its operations. A low battery indicator, displayed on the LCD screen, alerts you when battery replacement is necessary for accurate readings. When the indicator appears, promptly replace the batteries to maintain reliable performance.
To replace the batteries, locate the battery compartment on the back of the multimeter. Typically, this compartment is secured with a small screw. Unscrew and remove the compartment cover. Insert new batteries, ensuring correct polarity as indicated inside the compartment.
Use only batteries of the specified type. Incorrect battery installation can damage the meter. After replacing the batteries, securely reattach the compartment cover. A functioning meter with fresh batteries will display clear readings and a stable low battery indicator will disappear. Regularly check battery levels for optimal functionality.

Troubleshooting Common Issues
Common issues include no display or incorrect readings, often due to low batteries or overload protection activation; ensure proper operation and battery health.
No Display or Incorrect Readings
If the GDT-311 multimeter displays nothing, first verify the battery is correctly installed and has sufficient charge. A low battery indicator signals the need for replacement, ensuring accurate readouts. Incorrect readings can stem from selecting the wrong measurement range; always begin with the highest range and decrease for better precision.
Ensure the test leads are firmly connected to the appropriate terminals – common (COM) and the function-specific input. Check the leads themselves for damage, such as breaks in the insulation, which can cause inaccurate results. Overload protection may also trigger a lack of display or erroneous values if the input exceeds the selected range. If issues persist, try resetting the multimeter by removing and reinserting the battery.
Finally, confirm you are using the correct function (AC Voltage, DC Voltage, or Resistance) for the measurement you intend to take. Misselecting the function will naturally lead to incorrect or no display at all.
Overload Protection
The Gardner Bender GDT-311 multimeter incorporates overload protection to prevent damage to the instrument and ensure user safety. This feature activates when the input signal exceeds the maximum allowable limit for the selected range. When overload protection is engaged, the display may show “OL” or simply exhibit no reading, indicating the input is too high.
If you encounter an overload condition, immediately reduce the input signal or switch to a higher measurement range using the rotary dial. Do not attempt to continue the measurement until the overload indication disappears. Repeatedly exceeding the overload limits can potentially compromise the multimeter’s accuracy and lifespan.
This protection system is crucial for safeguarding against potentially harmful voltage or current levels. Always exercise caution when working with electrical circuits and prioritize selecting an appropriate range before initiating any measurement to avoid triggering the overload protection.

Gardner Bender Resources
For additional support and information, Gardner Bender provides accessible online instruction manuals and dedicated customer support at 800.624.4320, ensuring assistance.
Accessing Instruction Manuals Online
Gardner Bender prioritizes user accessibility by offering a comprehensive library of instruction manuals directly on their website. This resource allows users to easily download the GDT-311 manual, alongside documentation for a wide range of their electrical and wire management products.
Whether you require guidance on basic operation, troubleshooting steps, or detailed specifications, the online manuals provide complete information. The Instruction Manuals page is designed for straightforward navigation, enabling both professional electricians and DIY enthusiasts to quickly locate the relevant documentation.
These downloadable manuals cover essential aspects of product usage, ensuring safe and effective operation. Accessing the manual online eliminates the need to physically store paper copies, promoting convenience and environmental responsibility. Gardner Bender’s commitment to readily available resources empowers users to maximize the functionality and longevity of their products.
Contacting Gardner Bender Support (800.624.4320)
For personalized assistance with your Gardner Bender GDT-311 multimeter, or any questions regarding its operation or features, their dedicated support team is readily available. You can reach Gardner Bender directly by calling their toll-free number at 800.624.4320.
Their knowledgeable representatives can provide guidance on troubleshooting common issues, interpreting readings, understanding safety precautions, and navigating the manual’s instructions. Whether you encounter difficulties with AC/DC voltage measurements, resistance testing, or manual ranging, the support team is equipped to offer effective solutions.
This direct line of communication ensures that users receive prompt and accurate support, maximizing their confidence and satisfaction with the GDT-311. Gardner Bender’s commitment to customer service extends beyond providing comprehensive documentation, offering a valuable resource for resolving any challenges you may face.